TEHNOSERV doo
Company for Production, Mounting and Engineering , Subotica
About us Boilers Ventilation & Air Conditioning Contact Refferences

Hotwater-boiler type TKP

Hotwater boiler type TKP is designated for all type of coal of granulation size up to 50mm. The best efficiency is accomplished by using brown coal, granulation size 5-30mm. This boiler is designated for continual work with automatical guidance of the combustion. The coal is brought with the series of tape transporters(elevators) to the combustion chamber. The combustion is going on the fixed cast iron grid. Air combuston is provided with the fan which injects air in to the airspace under the cast iron grid and the brick. There is also the fan which conduits the smoke gases out, and this fan also with a help of pipes brings the air in to the chamber. The slag and ashes are taken to the ashtray by the spiral transporter. Smoke gases go through the frontal turning chamber, smoke pipes, exit chamber, fans, duster and chimney in to the atmosphere. The duster separates dust from the smoke gases. The spiral transporter is cooled by the boiler water with special circulation pump. Built in doors on the boiler enable easy approach for cleaning and maintenance. These boilers are designated for maximal working pressure of 4 bars nad for the temperature of the inflow and outflow water 110/90°C. These boilers are made out of quality boiler steel with two capes, and a water flows through all surfaces which are in contact with the hot smoke gases, and the doors are protected with the brick mass.The insulation is very good so the boiler has very small energy losses.

1. Acceptance basket
6. Framework
11. Smoke pipes
16. Casing with insulation
21. Exit chamber
2. Scroll transporter
7. Secondary air system
12. Revision opening

17. Starting conduit

22. Transporter cooling system
3. Working pump
8. Brick coating
13. Cleaning door
18. Security conduit 23. Filling and celaring connection
4. Primary air system
9. Flame stopper
14. Exterior cape
19. Returning conduit 24. Ashtray
5. Cast grill 10. Combustion chamber 15. Thermoinsulation 20. Smoke gases drain 25. Cleaning door

 

Boiler type
Capacity
Water quantity
B
B1 L
L1
L2
K
H
H1
D
C
G
I DIN
MDIN
J
Weight
 
kW
l
mm
col
t
TKP 500 500 2100 1550 1600 2700 3900 5000 650 1850 1950 130 250 400 100 50 1 4
TKP 1000 1000 3500 1850 1900 3500 4800 5900 650 2150 2250 1600 250 500 125 50 1 6.9
TKP 1500 1500 5800 2050 2100 4300 5650 6750 670 2350 2450 1800 250 620 150 65 1 9.2
TKP 2000 2000 7100 2300 2400 4600 6100 7400 700 2600 2700 2000 300 650 150 65 1 12.2
TKP 2500 2500 8200 2400 2500 4900 6500 8000 730 2700 2850 2100 350 700 200 80 1 16.3
TKP 3000 3000 9200 2500 2600 5200 6900 8500 750 2800 2950 2200 400 800 200 80 1 19
* The mass of the boiler is without fan and operation group

We keep the right to changes